| Research article summary (published 30 Jul 2002): |
Temporal pitch mechanisms in acoustic and electric hearing.
Full Abstract
Two experiments investigated pitch perception for stimuli where the place of excitation was held constant. Experiment 1 used pulse trains in which the interpulse interval alternated between 4 and 6 ms. In experiment 1a these "4-6" pulse trains were bandpass filtered between 3900 and 5300 Hz and presented acoustically against a noise background to normal listeners. The rate of an isochronous pulse train (in which all the interpulse intervals were equal) was adjusted so that its pitch matched that of the "4-6" stimulus. The pitch matches were distributed unimodally, had a mean of 5.7 ms, and never corresponded to either 4 or to 10 ms (the period of the stimulus). In experiment 1b the pulse trains were presented both acoustically to normal listeners and electrically to users of the LAURA cochlear implant, via a single channel of their device. A forced-choice procedure was used to measure psychometric functions, in which subjects judged whether the 4-6 stimulus was higher or lower in pitch than isochronous pulse trains having periods of 3, 4, 5, 6, or 7 ms. For both groups of listeners, the point of subjective equality corresponded to a period of 5.6 to 5.7 ms. Experiment 1c confirmed that these psychometric functions were monotonic over the range 4-12 ms. In experiment 2, normal listeners adjusted the rate of an isochronous filtered pulse train to match the pitch of mixtures of pulse trains having rates of F1 and F2 Hz, passed through the same bandpass filter (3900-5400 Hz). The ratio F2/F1 was 1.29 and F1 was either 70, 92, 109, or 124 Hz. Matches were always close to F2 Hz. It is concluded that the results of both experiments are inconsistent with models of pitch perception which rely on higher-order intervals. Together with those of other published data on purely temporal pitch perception, the data are consistent with a model in which only first-order interpulse intervals contribute to pitch, and in which, over the range 0-12 ms, longer intervals receive higher weights than short intervals.
Learn Faster Today Improve your study skills
Author information
Author/s: Carlyon, Robert P (RP); van Wieringen, Astrid (A); Long, Christopher J (CJ); Deeks, John M (JM); Wouters, Jan (J);
Affiliation: MRC Cognition and Brain Sciences Unit, Cambridge, England.
Journal and publication information
Publication Type: Journal Article; Research Support, Non-U.S. Gov't
Journal: The Journal of the Acoustical Society of America (J Acoust Soc Am), published in United States. (Language: eng)
Reference: 2002-Aug; vol 112 (issue 2) : pp 621-33
Dates: Created 2002/08/20; Completed 2002/10/17; Revised 2006/12/27;
PMID: 12186042, status: MEDLINE (last retrieval date: 12/26/2008)
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article (including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- Psychophysical measures in patients fitted with Contour and straight Nucleus electrode arrays.
3 Jan 2006 - Simultaneous recording of stimulus-frequency and distortion-product otoacoustic emission input-output functions in human ears.
30 Jan 2005 - Investigations on the tonotopy for patients with a cochlear implant and a hearing aid.
30 Dec 2004 - The role of intensity upon pitch perception in cochlear implant recipients.
29 Sep 2006 - Music perception by cochlear implant and normal hearing listeners as measured by the Montreal Battery for Evaluation of Amusia.
30 Jul 2008 - Speech and melody recognition in binaurally combined acoustic and electric hearing.
27 Feb 2005 - Temporal masking in electric hearing.
29 Nov 2005 - Sensitivity to isolated and concurrent intensity and fundamental frequency increments by cochlear implant users under natural listening conditions.
30 Mar 2006 - Effects of introducing unprocessed low-frequency information on the reception of envelope-vocoder processed speech.
30 Mar 2006 - Effect of electrode configuration on psychophysical forward masking in cochlear implant listeners.
29 Apr 2006
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.