Research article summary:

Clinical assessment of the Zeiss IOLMaster.

Abstract Extract:
PURPOSE: To compare axial lengths and intraocular lens (IOL) power calculations obtained with the Zeiss IOLMaster by 2 observers with different training grades and to assess the agreement between optical and acoustic biometry. SETTING: Department of ... (Full abstract text below)

Published 2003Mar in Journal: J Cataract Refract Surg (Language : eng)

Full Pubmed Extract

This information was retrieved, real-time, on your behalf from the public area of the Pubmed website:

1. J Cataract Refract Surg. 2003 Mar;29(3):518-22

Clinical assessment of the Zeiss IOLMaster.

Kielhorn I, Rajan MS, Tesha PM, Subryan VR, Bell JA

Department of Ophthalmology, Pembury Hospital, The Laser Eye Clinic, Kent, United Kingdom. ikielhorn@doctors.org.uk

PURPOSE: To compare axial lengths and intraocular lens (IOL) power calculations obtained with the Zeiss IOLMaster by 2 observers with different training grades and to assess the agreement between optical and acoustic biometry. SETTING: Department of Ophthalmology, Pembury Hospital, The Laser Eye Clinic, Kent, United Kingdom. METHODS: In this prospective study, optical biometry was performed twice in 79 patients: first by a qualified ophthalmic nurse and second by 1 of several health care assistants without formal nursing training. In the same group of patients, the qualified nurse also obtained ultrasonic measurements to compare the 2 clinical methods. RESULTS: There was a high correlation coefficient for axial length and IOL power measurements (0.99 each) between the experienced examiner and the inexperienced examiners. The coefficient of repeatability (2 SD) was 0.58 diopter (D) for IOL power (mean 0.04 D) and 0.07 mm for the axial length (mean 0.00 mm). The correlation coefficient of IOLMaster measurements with A-scan measurements done by the same experienced ophthalmic nurse was 0.97 for IOL power and 0.98 for axial length. The limits of agreement (mean +/- 2 SD) were between +0.50 and -2.40 D for IOL power calculations and between +0.7 mm and -0.2 mm for axial length measurements. CONCLUSIONS: Optical biometry showed excellent repeatability using different examiners regardless of their medical training. The agreement with ultrasonic measurements and the precision of the method need further evaluation.

PMID : 12663017 [PubMed - Indexed for MEDLINE]


This information is obtained from the National Library of Medicine (NLM). Abstract text and other information may be subject to copyright. Type "NLM copyright" into Google for more information.

Full Author Information

First NameLastNameInitials
IngridKielhornI
Madhavan SRajanMS
Peter MTeshaPM
Visva RajaSubryanVR
John ABellJA

Affiliation: Department of Ophthalmology, Pembury Hospital, The Laser Eye Clinic, Kent, United Kingdom. ikielhorn@doctors.org.uk

3rd Party provider links

Click the links below to go to related 3rd party information:

MESH categories and related page links

This article was linked to the MESH categories shown on the left below. The links on the right are related Memletics pages.

Category links from this article:

  • Biometry - instrumentation, methods
  • Clinical Competence
  • Diagnostic Techniques, Ophthalmological
  • Eye - anatomy & histology
  • Humans
  • Interferometry
  • Lenses, Intraocular
  • Light
  • Observer Variation
  • Ophthalmic Assistants
  • Ophthalmology - education
  • Optics
  • Prospective Studies
  • Reproducibility of Results
  • Sound
  • Specialties, Nursing
   

Related Memletics topics:

Links for this article

For links to places where you can get the full text of this article see links. Note there may be a subscription or fee required for access to the full text.

New! Using similar technology to this site, we have launched find-health-articles.com, targeting over 1 million health research article abstracts.

Related Articles

Here are some articles related to this one (by title keywords):

Keywords in this article:

acoustic, agreement, assess, assistants, axial, biometry, calculations, care, clinic, clinical, coefficient, compare, conclusions, correlation, department, different, diopter, examiner, examiners, excellent, experienced, eye, first, formal, grades, group, health, high, hospital, inexperienced, intraocular, iol, iolmaster, kent, kingdom, laser, lengths, lens, limits, mean, measurements, medical, methods, need, nurse, nursing, observers, ophthalmic, ophthalmology, optical, patients, pembury, performed, power, precision, prospective, purpose, qualified, regardless, repeatability, results, same, scan, sd, second, setting, study, training, twice, ultrasonic, united, zeiss

Also, see our new free speed reading online course (beta version)

© Advanogy.com 2003-2007 - All rights reserved. Terms of Use | Privacy Statement | Contact Us